Homelab Hardware Inventory
Gathered 2026-07-06 via SSH probe (all hosts) + Proxmox read-only API. Serials/DIMM/SMART captured only on nodes with passwordless sudo (compute5, compute6); the rest are pending a sudo pass.
PVE cluster — physical nodes (6)
| Node | IP | Model | CPU | RAM | Storage | iGPU | NIC |
|---|---|---|---|---|---|---|---|
| beast | .200 | Gigabyte X570 AORUS MASTER (BIOS F39) | Ryzen 9 5950X (16c/32t) | 128 GB | 2× Samsung 870 EVO 1TB SATA, 2× Crucial BX500 2TB SATA, 2× HGST 8TB USB HDD (USB-ZFS), Sabrent Rocket 4TB NVMe, Samsung 990 PRO 2TB NVMe | — (2× P2200 discrete, passed to VM 101) | 1 GbE |
| compute2 | .192 | Dell OptiPlex 3090 | i5-10500T (6c/12t) | 32 GB | Crucial MX500 1TB SATA, Samsung 970 EVO+ 1TB NVMe | UHD 630 | 1 GbE |
| compute3 | .193 | Dell OptiPlex 3080 | i5-10500T (6c/12t) | 32 GB | Crucial BX500 1TB SATA, Samsung 990 PRO 2TB NVMe | UHD 630 | 1 GbE |
| compute4 | .194 | Dell OptiPlex 7050 | i7-7700T (4c/8t) | 16 GB | Bliksem 120GB SATA, SK hynix PC601 1TB NVMe | HD 630 | 1 GbE |
| compute5 | .196 | Dell OptiPlex Micro Plus 7010 (SN 1JPM7Y3) | i7-13700T (16c/24t) | 32 GB DDR5-4800 | WD SN740 256GB NVMe (18% wear), SK hynix PC711 1TB NVMe | UHD 770 | 1 GbE |
| compute6 | .198 | GMKtec NucBox K10 | i9-13900HK (14c/20t) | 64 GB DDR5-5600 (2×32, A-DATA) | EDILOCA EN206 256GB SATA, Crucial P5 1TB + P3 Plus 1TB NVMe | Iris Xe | 100 Mb ⚠️ |
All PVE nodes on kernel 6.17.13-pve. beast = PVE master + NUT master, holds the GPUs and most critical guests.
Standalone physical hosts
- pbs (.153) — HP EliteDesk 800 G4 DM 35W, i5-8500T (6c), 32 GB, Samsung 870 EVO 1TB SATA + Samsung 990 EVO 1TB NVMe + USB drives backing the USB-ZFS datastores (1TB Toshiba MD1000, 2× Hitachi 3TB, Toshiba 2TB, WD10EZEX 1TB), 1 GbE. Proxmox Backup Server 7.0.0-3 — not a cluster member.
- pi4 (.227) — Raspberry Pi 4 (Cortex-A72 4c, 4 GB, 32 GB microSD), 1 GbE, aarch64. Off-host Prometheus watchdog.
Storage appliances
- TrueNAS Scale = VM 100 on beast (4 vCPU, 34 GB) — serves
tankover NFS (/mnt/Tank/Media→ media-server/mnt/media). Physical disk backing = beast's disks (exact passthrough map TBD). - Synology (.82) — external physical NAS (model TBD, no SSH). NFS
/volume1/PBS→ PBS datastore.
GPUs
- 2× NVIDIA Quadro P2200 (5 GB GDDR5 each) — physically in beast, PCI-passthrough to Media-Server VM 101 (driver 580.159.03). Used for Plex / Immich / Tdarr transcode.
- iGPUs for QuickSync: compute4 (HD 630) + compute6 (Iris Xe) run Tdarr nodes.
UPS (NUT master = beast)
- cyberpower1 — CyberPower CP1500PFCLCDa (1500 VA / 1000 W tower), ~31% load.
- cyberpower2 — CyberPower CP1500PFCRM2U (1500 VA / 1000 W rack), ~12% load.
Guest / workload allocation
PVE VMs & LXCs
- beast: 100 TrueNAS (4c/34G), 101 Media-Server (8c/17G/230G + 2 GPU), 102 dns-server LXC (Technitium), 103 nextcloud LXC (8c/9G), 104 nut LXC, 108 docker-node02 (8c/4G), 900 ubuntu-template (stopped).
- compute2: 106 docker-node01 (4c/6G), 107 ansible-control (2c/2G).
- compute3: 109 wazuh (4c/9G).
Host-level Docker on PVE nodes (NOT LXC-wrapped — pct list empty on these):
- compute4: tdarr-node.
- compute5: node-exporter.
- compute6: tdarr-node, diun, vikunja, speedtest-tracker, ntfy, node-exporter, netdata, glances, watchyourlan, linkding.
Notable findings / TODOs
- ⚠️ compute6 NIC runs at 100 Mb (ethtool-confirmed; the K10 has 2.5 GbE) — bad cable/switch port.
speedtest-trackerruns on this node, so its WAN results are capped/misleading. Fix the cable/port. - beast concentration / SPOF — PVE master + NUT master + GPUs + TrueNAS + Media-Server + Nextcloud + DNS all on one machine.
- Kernel skew — docker-node01/02 + ansible-control on 6.8.0-111 (pending update); media-server 6.8.0-134; PVE nodes 6.17.13-pve.
- Deferred (need root sudo): serials/DIMM/SMART on beast, compute2, compute3, compute4, pbs; TrueNAS
tankdisk-passthrough map; Synology model.